• VIET | ENG
  • ×

    Differential flow measuring device

Rosemount™ 3051SFC Compact Conditioning Orifice Plate Flow Meter

0 VND

  • Product code: F-DPS[100001]
  • View: 201
  • Unit: pcs
  • Status: Contact
  • Producer: Emerson/Rosemount™

Product details

Features:

  • Designed with built-in flow calculations for direct reporting of fully-compensated mass flow
  • Patented 4-hole orifice plate design enables accurate flow measurement in turbulent flow profiles
  • Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements
  • Advanced diagnostics provide diagnostic coverage to detect abnormal process conditions and electrical loop issues
  • Callendar-Van Dusen sensor matching improves temperature accuracy enabling best-in-class flow calculations
  • Ultra for Flow performance class enables optimized flow measurement with a ±0.04% of reading accuracy
  • All-welded, SuperModule™ design offers industry-leading accuracy in harsh environments and applications
  • Flowmeters come fully configured, leak-tested and ready to install right out of the box for fast installation
  • Self-centering mechanisms of orifice plate simplify installation and ensure optimal flow measurement accuracy
  • Orifice plate does not require impulse lines, special flanges or piping modifications for cost-saving efficiency
  • SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations

Aplications: 

The Rosemount 3051SFC Compact Conditioning Orifice Plate Flow Meter is a no-equal solution for multivariable measurement, obtaining direct variable measurements in combinations of differential pressure, static pressure and process temperature. This flow meter comes with a patented, 4-hole conditioning orifice plate for accurate measurement in turbulent flow conditions. This orifice plate also reduces pipe straight run, requiring only two pipe diameters (2D) upstream and downstream of the plate.

SPECIFICATIONS
Range down Up to 200:1 (14:1 flow turndown)
Measurement Range Up to 2000 psi (137,89 bar) differential, Up to 3626 psia (250,00 bar) absolute, Up to 3626 psig (250,00 bar) gage
Line Size 2 to 12 in. (50 to 300 mm)
Output Differential pressure, static pressure, process temperature, scaled variable, mass flow, volumetric flow, energy flow
Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus
Process Wetted Material 316 SST
Sensor material SST 316 or alloy C-276
Connection cable Optional without cable or cable (50 ft. (15 m) - 100 ft. (31 m))
Diagnostics Basic Diagnostics, Loop Integrity, Process Intelligence, Plugged Impulse Line
Certifications/Approvals SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE, hazardous location, see full specs for complete list of certifications
Download Catalogue https://www.emerson.com/documents/automation/flyer-rosemount-3051s-multivariable-transmitter-en-5236912.pdf