Product
Featured Products
Differential flow measuring device
Product details
Features:
- Complete flow assemblies are leak-tested and calibrated to reduce leak points up to 70% and simplify installation
- Orifice plate built with patented 4-hole design for accurate flow measurement downstream of flow disturbances
- Innovative orifice plate requires only 2D upstream and downstream to reduce pipe straight-run requirements
- Local operator interface offers easy-to-use menus and built-in configuration buttons for streamlined commissioning
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
Aplications
The Rosemount 2051CFC Compact Conditioning Orifice Plate Flow Meter is an industry-standard solution for reliable flow measurements. With a patented, 4-hole design, the compact conditioning orifice plate of this flow meter ensures dependable data downstream of disturbances and requires only two pipe diameters (2D) upstream and downstream for a reduced pipe straight run. This flow meter also features a local operator interface (LOI) for easy field commissioning.
SPECIFICATIONS | ||
---|---|---|
Warranty | Up to 5-year limited warranty | |
Rangedown | Up to 100:1 (5:1 flow turndown) | |
Measurement Range | Up to 1000 inH2O (2,48 bar) differential | |
Line Size | 2 to 12 in. (50 to 300 mm) | |
Output | Differential pressure, scaled variable | |
Communication Protocol | 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V Low Power HART® | |
Process Wetted Material | 316 SST | |
Diagnostics | Basic Diagnostics | |
Certifications/Approvals | SIL 2/3 certified to IEC 61508 by an independent 3rd party, NACE®, hazardous location, see full specs for complete list of certifications | |
Download Catalogue |